No, the same line sizes used for R-22 are used for R-410A. The ideal line size for R-410A is smaller in diameter than R-22 tubing and falls between the standard available nominal refrigerant tubing sizes. The same tubing sizes used for R-22 must be used for R-410A to avoid excessive pressure drops when using the next smaller tube.Saturation Pressure-Temperature Data for R410A (psig)*.What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system.Filter is new. suction pressure is about 85 which seems low and head pressure is about 230 which seems ok. Super heat goes all over the place from 6 to 16. do you think I have a refrigerant restriction? Any help is greatly appreciated. Thanks. ... My 410a system keeps freezing up. Filter is new. suction pressure is about 85 which … Constants for vapor pressure of saturated vapor (dew point), p g: A = –1.440004 E+00 E = –3.521484 E+00 B = –6.865265 E+00 F = –7.750000 E+00 C = –5.354309 E–01 X o = 2.086902 E–01 D = –3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ... Nov 11, 2022 · 2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2. These liquid-line restrictions all cause the evaporator, compressor, and condenser to be starved of refrigerant. This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control;the heat content of the return air (including the sensible temperature) drops, the saturated suction temperature will drop, resulting in a drop in suction pressure. As the suction pressure falls to 120psig the APR Control will begin to open and attempt to stabilize the system suction pressure at approximately 120psig.Sep 18, 2020 · The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits. The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures. Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the high-side (discharge) pressure may range from 300 to 450 psi, depending on factors such as temperature and load. What is the pressure at 100 degrees on 410A?to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sds• Protected compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor, and externally by the system high and low pressure …Jun 7, 2014 · 410a ductless mini split operating pressures. I know that you should rarely put gauges on a ductless mini split, and that you should dump the charge and just weigh it in. I have heard that there are spec sheets that will give you "normal operating pressures" based on indoor and outdoor conditions. This would come in handy when servicing systems ... When it comes to choosing a hand held vacuum, there are several factors that determine its strength and effectiveness. From suction power to battery life, each feature plays a cruc...A R-410A evaporator running below 100 psig will freeze-up just like its R-22 cousin. One of the most common causes of low suction pressure is loss of critical refrigerant charge caused by small leaks over time. Explore heat pumps, heat pump reviews, costs, brands, manufacturers, knowledge, questions, visit heatpumpmeta.com.A R-410A evaporator running below 100 psig will freeze-up just like its R-22 cousin. One of the most common causes of low suction pressure is loss of critical refrigerant charge caused by small leaks over time. Explore heat pumps, heat pump reviews, costs, brands, manufacturers, knowledge, questions, visit heatpumpmeta.com.View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec. ... Low Suction Pressure Moisture freezing and blocking valve Recover charge, install filter-drier, evacuate system, ...• supply tee for suction line connection ... to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sds.This would typically cause a low suction pressure, and a low superheat. In heat mode, a dirty air filter causes low airflow across the condenser. ... this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient. This means if it is 50˚ outside the suction ...2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2.If the suction pressure is 45 psi, (which converts to 22 ° F) and the suction temp is 32 ° F, the system still has 10 ° F of superheat. The fact that these readings are normal indicates the low suction pressure is not caused by low refrigerant, but insufficient heat getting to the evaporator. CAUSE #2: Defective, plugged, or undersized ... In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera... connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid …The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ...May 5, 2016 · The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice. My operating pressures are 315/85... The suction is too low for 410A but it is maintaining a 15-18 degree SH and a 10-12 degree SC The weird thing is the suction temp drops to 32-34 and is causing ... low superheat, low subcooling, low discharge superheat low to normal suction pressure...all the liquid is. In the evaporator. "If history repeats ...Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.If you don't mind getting your hands a little dirty, some petroleum jelly can increase the suction power of your plunger to help with particularly stubborn clogs. If you don't mind...Cleaning services are always in demand and there are many different segments in the industry, here is how to start a pressure washing business. If you buy something through our lin...May 21, 2021 ... 410A single refrigerant PT chart here https://www.es-refrigerants.com/docs/29132_585.pdf Esco Chart here ...We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG.Calculate. This free online tool allows HVAC professionals to quickly calculate Superheat and Subcooling measurements for both R22 & R410A refrigerants.This will allow you to measure the suction line temperature during the charging process. Step 2 – Taking Measurements Measure Suction Line Temperature. With your temperature probe in place, measure the ... Refer to a 410A pressure-temperature chart or use an HVAC app to convert the high-side pressure reading to the corresponding saturation ...pressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), andpressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), andThe recommended high-pressure control settings are a cut-out pressure of 610 psig and a cut-in pressure of approximately 500 psig. The recommended low …May 8, 2017 · Find out what causes high suction pressures and the consequences of high suction pressure. We examine the refrigeration cycle and work to solve the root of high suction pressure 410a problems. Read more with HVAC Brain. Discharge line temperature 150°F (65°C) or higher at the end of the freeze cycle. Discharge line temperature less than 150°F (65°C) at the end of the freeze cycle or Compressor shell is frosted. Evaporator Outlet Temperature Comparison. Attach and insulate temperature probes between evaporator outlet and 90° elbow.2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2.November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the newer ...Bryant 5 ton split, R410a, new evap, new outdoor unit, new line set. system evacuated and charged to factory specs. suction pressure at 95 psi, discharge pressure at 300 psi. sub cooling measures 21 d …Theoretical calculations reveal that at the above high-temperature cooling conditions, a 2-psi suction pressure drop produces about 2% loss of efficiency and 2.4% loss of capacity in an R-22 system. But in an R-410A system, the suction pressure drop can be allowed to go as high as 3.1 psi before the same losses in performance are seen.Nov 11, 2022 · 2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2. Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably …Suction pressure control — loss of charge P170AA-400C SPST Open Low 100 470 690 Fan cycling for head P170CA-400C SPST Open High 200 610 690 ... PRESSURE CONTROLS COMPATIBLE WITH R-410A COMMERCIAL REFRIGERATION CONTROLS * Maritime models for use with corrosive media. ** Low-flow model.Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p ... Temperature-Pressure Chart.xlsx Author: Baran Created Date: 12/24/2014 11:21:46 AM ...Theoretical calculations reveal that at the above high-temperature cooling conditions, a 2-psi suction pressure drop produces about 2% loss of efficiency and 2.4% loss of capacity in an R-22 system. But in an R-410A system, the suction pressure drop can be allowed to go as high as 3.1 psi before the same losses in performance are seen.What is the r410a’s standing pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. What is the best 410a ...In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or evaporator or condenser ...Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p ... Temperature-Pressure Chart.xlsx Author: Baran Created Date: 12/24/2014 11:21:46 AM ... (R-508B) is a better replacement than Freon™ 410A. Properties Freon™ 410A is safe to use when proper storage and handling practices are followed. It is a nonflammable, low toxicity mixture of HFC-32 and HFC-125 (50/50 wt%). Freon™ 410A has been classified as A1 by ASHRAE and assigned the ASHRAE number of R-410A. It has been Low-side air conditioner compressor motor pressure: This is the pressure in the air conditioner's refrigerant suction line (low side pressure during compressor operation) and this will be a relatively low number, often less than 100 psi. During operation, refrigerant is returning to the compressor from the cooling (evaporator) coil in this line. Mini Split R410a Low Side Suction Charging Service Gauge Hose Set 5/16" Port. 91 Reviews. SKU: PGML-5/16B1/4Y. Free Shipping for Orders Above $49. Wholesale Price Directly From Factory. Secure and Versatile Payment Options. In stock, ready to ship. Price $35 52 $29 99 Save $5.53. Buy in monthly payments with Affirm on orders over $50. system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.Newly released blood pressure suggestions recommend lifestyle changes as a first step toward achieving healthy levels. Trusted Health Information from the National Institutes of He...The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ...Since R410A refrigerant is charged under higher pressure, charging an R22 system with it will increase the force within the coolant lines. The pressure can become high enough for parts of the system to rupture. At the very least, leaks will occur. Mixing refrigerants is not an option either. This will contaminate the system, and the R22 will ...This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, ... R410A PT Chart: -60°F To +155°F Pressure Temperature Chart; R22 PT Chart: Pressure Temperature Chart For -60°F To +155°F; R454B PT Chart: Pressures At -40°F To 150°F ...system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up …The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi. Why this ...Refrigeration Research, Inc. is pleased to announce new, A.S.M.E. certified suction accumulators intended for use with R410A refrigerant. A.S.M.E. suction accumulators available in standard sizes and volumes, to make your transition to R410A as seamless as possible. All A.S.M.E. suction accumulators are finished with corrosion-resistant powder …to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sdsWhat should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.Take the suction pressure and use the pressure/temperature chart to convert it to temperature. Let’s say the suction pressure is 60(Psi) which converts to 34F. And assuming that the suction line temperature is 44F. Then to get superheat we just get the difference between the two temperature readings. In this case, we have 10F of superheat.R410A Pressure Temperature Chart (In Fahrenheit) Printable PDF Temp er atu r e (° F ): R410A P r essu r e (p si g ):-60 ° F 0. 9 psi g-55 ° F 1. 8 psi g-50 ° F 4. 3 psi g-45 ° F 7. 0 psi g-40 ° F 10. 1 psi g-35 ° F 13. 5 psi g-30 ° F 17. 2 psi g-25 ° F 21. 4 psi g-20 ° F 25. 9 psi g-18 ° F 27. 8 psi g R-410A and R-22 is the higher operating pressures (approximately 50% higher on both the discharge side and the suction side).For example, a high-efficiency condensing unit using R-22 typically operates with a suction pressure of about 68 psi and a discharge pressure of about 250 psi at an outdoor temperature of 95°F. What Determines High Head Pressure. A 410A system who have 400-418 PSIG on the high side, while the lower side is 120-130 PSI. If it is more than this, it is considered high. ... Suction pressure increases; On the suction side, there is fluttering pressure; High head pressure can also cause noises; Condenser piping can have …In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...’ve highlighted 117 PSIG in the chart above. It’s a ballpark figure of where the suction pressure could be on an R-454B system. The P-T chart tells us that the suction saturation temperature (SST) for an R-410A system is 39.4°F at that pressure. R-32 is very close behind at 38.3°F. R-454B is a little higher at 44.6°F.I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425. liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure Never install suction- line filter drier in the liquid- line of an R-410A system.! CAUTION 7. If suction-line filter drier was installed for system clean up, operate system for 10 hr. Monitor pressure drop across drier. If pressure drop exceeds 3 psig, replace suction-line and liquid-line filter driers. Be sure to purge system with dry nitrogen ...The upright vacuum cleaner remains the standard, with great suction power. Here are the best upright vacuums from Dyson, Shark and others. By clicking "TRY IT", I agree to receive ...R410A systems are much less forgiving, and the only way to get a perfectly charged system is with superheat and subcooling probes. Nonetheless, the low-pressure side should read between 102 and 145 PSI. Anything below this will cause the refrigerant and lines to freeze up. ... Instead, it measures the indoor air handler's suction pressure …Forane 410A Pressure Temperature Chart. Saturation Pressure-Temperature Data for R-410A (psig)*.Bryant 5 ton split, R410a, new evap, new outdoor unit, new line set. system evacuated and charged to factory specs. suction pressure at 95 psi, discharge pressure at 300 psi. sub cooling measures 21 d …In this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction such as vapor satur...SUBJECT: TEMPERATURE - PRESSURE CHART FOR FYI #289 9/17/2009 R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS ADVANTAGE Engineering, Inc.525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 web site: www.AdvantageEngineering.com email: [email protected] 8, 2020 ... In this HVAC Video, I Show SEVERELY UNDERCHARGED, UNDERCHARGED, CORRECTLY CHARGED, and OVERCHARGED Scenarios on a Running R-410A Refrigerant ...R-410A refrigiant. The Suction pressure temperature chart in the Condensing Unit installation & service reference that came with the unit only goes up to 80 psig, yet I'm seeing 135 psig at the low side service valve. Looking elwhere I found that 135 psig is 47F. High side 285 psig which is 92F. Spec is SH 7-9F and SC 7-9F (using TXV). …Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F.Temperature (°F): R410A Pressure (psig): -60 °F. 0.9 psig. -55 °F. 1.8 psig. -50 °F. 4.3 psig. liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure

liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure . Miles pfeffer bucks county

suction pressure for 410a

For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 compressor can replace with R410A. by Mohammed Awais haji Latif.The pressure of R-410A is so high that if your hand gets in the way of a leak, it could cut a finger off. This is a myth, as well as a physical impossibility. Devices such as insulin jet injectors require 7,000 to 10,000 psi pressures to puncture the skin and 16,000 to 25,000 psi pressure spikes are normally used. Mini Split R410a Low Side Suction Charging Service Gauge Hose Set 5/16" Port. 91 Reviews. SKU: PGML-5/16B1/4Y. Free Shipping for Orders Above $49. Wholesale Price Directly From Factory. Secure and Versatile Payment Options. In stock, ready to ship. Price $35 52 $29 99 Save $5.53. Buy in monthly payments with Affirm on orders over $50. Liposuction is the removal of excess body fat by suction using special surgical equipment. A plastic surgeon typically does the surgery. Liposuction is the removal of excess body f...So we replace the compressor (same model #), replace the liquid line filter dryer, and evacuate to 500 microns. I weigh the charge in per the manual = unit's orignal charge + addl ounces per foot of lineset - total of 5# 6 oz. Start unit up, damn it, looks wrong immediatelY: Suction: 149.5 psi. Suction Temp: 55.4*F.I have high suction pressure and slightly low to correct head pressure. It is a heat pump operating in heat mode. Filters are clean and indoor coil is clean as well. ... R410a Copeland scroll (single speed with bypass for two stages cooling). Running on high, Suction 140 psig, liquid 300 psig, superheat 9F, ...Jul 9, 2015 ... R-410A AC Unit, Checking the Charge with Subcooling, Undercharged through Overcharged! AC Service Tech LLC•113K views · 4:22. Go to channel ...If you’re like 1 out of 3 Americans living with high blood pressure, then you and your doctor would probably be happy to see your blood pressure get lower. But is there such a thin...Saturation Pressure-Temperature Data for R410A (psig)*. Temp (°F) Pressure. Temp (°C)What would be the approximate refrigerant pressure of an R-410A machine at (80°F) room temperature while that machine is idle? A. 143 PSIG B. 212 PSIG C. 238 PSIG D. 260 PSIG and more. ... Lower suction pressure B. Higher suction pressure C. Lower discharge pressure D. Higher discharge pressure. D. Higher discharge pressure. 59. What is the ...Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and …Jul 9, 2015 ... R-410A AC Unit, Checking the Charge with Subcooling, Undercharged through Overcharged! AC Service Tech LLC•113K views · 4:22. Go to channel ...Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.The upright vacuum cleaner remains the standard, with great suction power. Here are the best upright vacuums from Dyson, Shark and others. By clicking "TRY IT", I agree to receive ....