Common array manager software - 1. Use the IP address of the management host to access the management software: https://cam-management-host:6789 2. Log in as root (Solaris OS) or Administrator (Windows). The Oracle Java Web Console page is displayed. Next Steps Go to the Sun Storage Common Array Manager Software Installation and Setup Guideor Online Help for information

 
See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS.. Taxis in my area

Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version …Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed. 2 Sun StorageTek Common Array Manager Software 6.5.0 Release Notes • September 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM includes a distributed architecture which enables you to manage Sun Storage Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] ... [TM] Configuration Service or CAM Software., or SANtricity ES Storage Manager Solution Steps to Follow Every volume built on an Sun StorageTek [TM] 6000/25x0 array line has two properties, a "preferred controller" and an ...2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.Goal. This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …The Common Array Manager software can manage arrays with either in-band and out-of-band connections at the same time. Copying Configuration Files and In-Band Management. If you are going to copy a configuration file to a management host that will have in-band communication with the array, ...5. If needed, change the array management default IP addresses using the serial port interface. Configuring IP Addressing. 6. Install the Sun StorageTek Common Array Manager software. 7. In the software, register the storage array and perform the basic administration setup. Note: for storage array configuration, use the iSCSi steps that follow. Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. Select Sun Storage Common Array Manager Software 6.10, and download the software. For detailed MOS download steps, see the knowledge article “How to Download Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note - Each array should be managed by one CAM management host only. Download popular programs, drivers and latest updates easily No specific info about version 6.9. Please visit the main page of Sun Storage Common Array Manager CLI on Software Informer.https://cam-management-host:6789. cam-management-host is the IP address or host name of the host where you installed the Common Array Manager software. 3. Log in as root (Solaris) or administrator (Windows). For Solaris OS and Linux, root already exists for the machine on which you installed the software.See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS.Sun StorageTek Array Administration Guide For Sun StorageTek Common Array Manager, Release 6.2: PDF: Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family: HTML: PDF: Sun StorageTek Common Array Manager User …Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation OptionsNote: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest.FCAP Array is a powerful, scientific analysis software designed for Cytometric Bead Array (CBA) data. The software contains tools for all of the jobs you need to easily and …The array management software saves the configuration to allow access control between the specified SAS ports and targets. 7. Click Export to save the configuration to a template (see the Online Help for more information about creating SAS Access Configuration templates. ... Sun Storage Common Array Manager saves the current SAS domain ...Sun Storage Common Array Manager software models the aggregated connections as a single, logical SAS port. The information displayed in the Access Configuration Summary only lists the connected port with the higher alphanumeric sort. For example, if Ports 0 and 2 are connected into the same expander, only Port 2 is listed.Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur.Sun StorageTek Array Administration Guide For Sun StorageTek Common Array Manager, Release 6.2: PDF: Sun StorageTek Common Array Manager CLI Guide, Release 6.2.0: HTML: PDF: Sun StorageTek Common Array Manager CLI Guide for the J4000 Array Family: HTML: PDF: Sun StorageTek Common Array Manager User … 快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。. Sun StorageTek 2500 Series Array Regulatory & Safety Manual. HTML. PDF. Sun Storage Common Array Manager Software 6.10 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.9 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.8 Documentation. LIBRARY.The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …Service Advisor integrated with the Sun StorageTek Common Array Manager software. Reference information for the CLI Sun StorageTek Common Array Manager CLI Guide sscs man pages. Preface xiv Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in thisThe Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …Download popular programs, drivers and latest updates easily Sun Storage Common Array Manager Online Help is a software that provides a simple, unified interface for managing Sun Storage arrays. It simplifies deployment, simplifies the storage environment, and increases utilization. Sun Storage Common Array Manager Software Release Notes. Use this document for instructions about how to download the latest Oracle’s Sun Storage Common Array Manager software and learn about new features, related documentation, system requirements, notable bug fixes, and known issues for the CAM 6.9.0_20 product release. The Sun StorageTek Common Array Manager (CAM) software suite is your main tool for Sun Storage array enclosure management, monitoring, and service capabilities. The software has both a secure browser interface and a command-line interface (CLI). CAM is supported for use with Solaris, Linux and Windows platforms. Viewing Sun Storage …How to Download Common Array Manager (CAM) Software and Patches [ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using the Sun Storage Common Array Manager software, version 6.9.0.Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation Options Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web browser interface is the primary interface for configuring, managing, and monitoring the system. Two command-line interfaces options are also provided. 2 Sun StorageTek Common Array Manager Software 6.4.1 Release Notes • August 2009 About CAM The Sun StorageTek Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes the following: Browser interface Local command …The array management software saves the configuration to allow access control between the specified SAS ports and targets. 7. Click Export to save the configuration to a template (see the Online Help for more information about creating SAS Access Configuration templates. ... Sun Storage Common Array Manager saves the current SAS domain ...Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.Common Array Manager User Guide for the J4000 Array Family Version 6.1.2 Part No. 820-3765-11 August 2008 Revision A. ... TABLE B-4 Common Array Manager Software Installation Commands 125. xiii Preface The Sun StorageTek Common Array Manager User Guide for the J4000 Array Family is aNote - For other arrays managed by the Sun StorageTek Common Array Manager, firmware, this release may require special firmware instructions. Refer to the Sun StorageTek Common Array Manager Software Release Notes, Release 6.1.2 (or later) for the latest firmware information and a list of firmware files for your array.Prerequisite for Windows Storage Management Stations:If you have an earlier version of storage management software (other than CAM) loaded onto your Windows operating system, uninstall it before using the upgrade utility. The Common Array Manager software is the only supported storage management software for the 2500 Series array.5. From the Oracle Java Web Console page, select Sun Storage Common Array Manager from the Storage section of the Oracle Java Web Console page. Providing Site Information. When you open the Common Array Manager after a first-time installation, the General Configuration page displays. 1. Enter the required site and contact information for your site.The intent of this document is to explain how to download Common Array Manager (CAM) and its patches from My Oracle Support (MOS) - Patches & Updates. The 3 steps are: …The Common Array Manager software can manage arrays with either in-band and out-of-band connections at the same time. Copying Configuration Files and In-Band Management. If you are going to copy a configuration file to a management host that will have in-band communication with the array, ... Sun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version 6.1.2: HTML: PDF The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage arrays. New features in Release 5.1.3: Sun Connection (Auto Service Request): registration, telemetry, and automated case generation. Support for 2500 Series Arrays.Sun Storage Common Array Manager (CAM) - Version 6.0 and later: Sun StorageTek[TM] Flexline 380 (FLX380) with Common Array Manager ... reference can be used by end-user and all levels of support personnel for purpose of verifying component firmware and management software compatibility. For instructions to download CAM, ... 2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are also ... CAM is a software application that allows you to manage SAS-NEMs. and disk blades in a chassis from one central point. It is written. in Java so you can run it on any platform. …Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to … Sun Storage 2540 Array - Version Not Applicable and later Sun Storage Flexline 380 Array - Version Not Applicable and later All Platforms Goal. Automatic Service Request (ASR) is a feature of the array management software that monitors the array system health and automatically notifies Oracle when critical events occur. xii Sun StorageTek Common Array Manager Software Installation Guide • January 2007 How This Book Is Organized Chapter 1 provides an overview of the Sun StorageTek Common Array Manager software and installation process. Chapter 2 describes how to install the Common Array Manager software and the local and remote host management software. The intent of this document is to explain how to download Common Array Manager (CAM) and its patches from My Oracle Support (MOS) - Patches & Updates. The 3 steps are: …Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation OptionsSun StorageTek Common Array Manager Software Release Notes, Release 6.1: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.1: HTML: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.1: PDF: Sun StorageTek Common Array Manager User Guide for the J4000 Array Family, Version …Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... This chapter describes two types of complete installation of Common Field Manager software: Off a local senior host; On a central management server These procedures … Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using ... The Sun StorageTek Common Field Manager User Guides for of J4000 Array Family is a combined software installation the user guide. This guiding describes like to install management and configuration soft. Sun StorageTek Common Array Corporate User Guide since the J4000 Alignment Family: HUNDRED H A P T E R ...Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.SANtricity Storage Manager. SANtricity ES Storage Manager 10.77 Software and Array Documentation l. SANtricity Storage Manager 8.3x l. Sun Storage Common Array Manager Software. Sun Storage Common Array Manager 6.10 l. Sun Storage Common Array Manager 6.9 l.Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet … How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM. The SAS expander on the Virtualized Multi-Fabric 10GbE NEM is SES-2 compliant. These enclosure management features are available through the management software called the Sun Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification Install Oracle's Sun Storage Common Array Manager 6.9.x software and perform initial configuration for RAID and JBOD open systems storage arrays. Download. Sun Storage Common Array Manager Array Administration Guide, Version 6.9.0. This document describes how to configure and monitor Oracle's Sun Storage, StorageTek, and FlexLine arrays using ... Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not. The Sun StorageTek Common Array Manager Software Installation Guide is a combined software installation and initial configuration guide. This guide describes how to install management and configuration software, and how to perform initial storage planning and configuration. Consult the hardware installation guide for your array To Assign an IP Address to Each Ethernet Port. . Access the Sun StorageTek Common Array Manager software: Open a web browser and enter the IP address of the management host: https://management-host:6789. management-host is the IP address of the machine where you installed the management software.Sun StorageTek Common Array Manager Software Release Notes, v6.0.1: HTML: PDF: Sun StorageTek Common Array Manager Software Release Notes, v6.0: HTML: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.0: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.0: PDFSun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: ... [TM] Configuration Service or CAM Software., or SANtricity ES Storage Manager Solution Steps to Follow Every volume built on an Sun StorageTek [TM] 6000/25x0 array line has two properties, ...1 Sun StorageTek ™ Common Array Manager CLI Quick Reference For the Sun StorageTek™ 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and 380 Systems This document lists the sscs(1M) subcommands that you can use to administer the Sun StorageTekTM 6130, 6140, 6540, 2500 Series Arrays, and FlexLine 240, 280, and …Sun StorageTek Common Array Manager Software Release Notes, Release 6.1.2 ...Sun Storage Common Array Manager (CAM) has the ability to collect support-based configuration and logs for Sun Storage 2500, 2500-M2, J4000, F5100, 6000 and Flexline Arrays. ... Instead, you use the management software provided with the Unified Storage System. Please refer to J4200/J4400 Array System Overview. Solution. … 表 1.1. Sun Storage Common Array Manager 内容 类型 版本 Sun Storage Common Array Manager 6.10 Oracle Java Web Console 软件 3.1 Apache Tomcat for Solaris 6.0.37 Jetty Web 服务器 7.6.12 Oracle Java 2 软件开发工具包 1.6.0_71 固件文件 请参见《Sun Storage Common Array Manager Baseline Firmware Reference, Version 6.10》 3. Install the desired version of the Common Array Manager software as described in the Installation Guide in the doc directory of the software installation CD or download. Note –The procedure will be similar to “Installing the Common Array Manager Software” on page 7, but the prior release may have differences. 4. Uninstall all previous versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.0 release. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet port of either array controller. 2 Sun Storage Common Array Manager Software 6.8.1 Release Notes • September 2011 About the Software Sun Storage Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor storage arrays. The software includes a distributed architecture enabling you to designate local and Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation OptionsDell Array Manager is storage management software that provides Array, Disk, Volume and Enclosure management functions. Through a common interface Array Manager let's you configure and manage local and remote storage attached to your system while your system remains online. Dell Array Manager is a software tool for installing and …Sun StorageTek Array Administration Guide, Version 6.5.0. PDF. Sun StorageTek Common Array Manager User Guide for Open Systems. HTML. PDF. Sun StorageTek Common Array Manager CLI Guide, Version 6.5.0. HTML. PDF. Sun StorageTek Common Array Manager Software 6.5 Product Library Documentation.https://cam-management-host:6789. cam-management-host is the IP address or host name of the host where you installed the Common Array Manager software. 3. Log in as root (Solaris) or administrator (Windows). For Solaris OS and Linux, root already exists for the machine on which you installed the software.5. From the Oracle Java Web Console page, select Sun Storage Common Array Manager from the Storage section of the Oracle Java Web Console page. Providing Site Information. When you open the Common Array Manager after a first-time installation, the General Configuration page displays. 1. Enter the required site and contact information for your site.The Sun StorageTek Common Array Manager Installation Software CD provides three installation-related wizards: GUI software installer - Enables you to use a graphical user …The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage systems, including the Sun StorageTek 6140 Array. You can also use the Common Array Manager software to diagnose problems, view events, and monitor the health of your array.See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS.Sun Storage Common Array Manager provides several storage profiles that meet most storage configuration requirements. By default, the New Volume wizard will allow you to select a default pool with its default profile of RAID-5 characteristics. The profiles that display are specific to the model of the array and the drives it supports.Sun StorageTek Common Array Manager Software Release Notes. This document contains important information about Release 6.0.0 of the Sun StorageTek Common Array Manager software or information that was not available at the time the product documentation was published. Read this document so that you are aware of issues or …The Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage systems, including the Sun StorageTek 6140 Array. You can also use the Common Array Manager software to diagnose problems, view events, and monitor the health of your array.

. Norway translation

common array manager software

Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet …Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another might require special procedures.How to Download Common Array Manager (CAM) Software and Patches [ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a …CAM is a software application that allows you to manage SAS-NEMs. and disk blades in a chassis from one central point. It is written. in Java so you can run it on any platform. …Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.Sun StorageTek Array Administration Guide, Version 6.5.0. PDF. Sun StorageTek Common Array Manager User Guide for Open Systems. HTML. PDF. Sun StorageTek Common Array Manager CLI Guide, Version 6.5.0. HTML. PDF. Sun StorageTek Common Array Manager Software 6.5 Product Library Documentation. Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ... The Common Array Manager software can manage arrays with either in-band and out-of-band connections at the same time. Copying Configuration Files and In-Band Management. If you are going to copy a configuration file to a management host that will have in-band communication with the array, ...Goal. This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …Overview of the sscs Command. The sscs command-line interface (CLI) enables you to manage and monitor disk arrays. The CLI can be installed on a local data host or a remote management host.. There are two forms of the CLI: Local CLI This is the version used in a CLI-only installation of Sun Storage Common Array Manager, and should be used if …Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation Options.

Popular Topics